CVE-2022-50827

In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Fix memory leak in lpfc_create_port() Commit 5e633302ace1 ("scsi: lpfc: vmid: Add support for VMID in mailbox command") introduced allocations for the VMID resources in lpfc_create_port() after the call to scsi_host_alloc(). Upon failure on the VMID allocations, the new code would branch to the 'out' label, which returns NULL without unwinding anything, thus skipping the call to scsi_host_put(). Fix the problem by creating a separate label 'out_free_vmid' to unwind the VMID resources and make the 'out_put_shost' label call only scsi_host_put(), as was done before the introduction of allocations for VMID.
CVE-2022-50827Linux

CVE-2022-50827

In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Fix memory leak in lpfc_create_port() Commit 5e633302ace1 ("scsi: lpfc: vmid: Add support for VMID in mailbox command") introduced allocations for the VMID resources in lpfc_create_port() after the call to scsi_host_alloc(). Upon failure on the VMID allocations, the new code would branch to the 'out' label, which returns NULL without unwinding anything, thus skipping the call to scsi_host_put(). Fix the problem by creating a separate label 'out_free_vmid' to unwind the VMID resources and make the 'out_put_shost' label call only scsi_host_put(), as was done before the introduction of allocations for VMID.

CVSS
-
EPSS
9.75%
Aktywnie wykorzystywana
brak w KEV
Produkt
-

Co wiadomo

In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Fix memory leak in lpfc_create_port() Commit 5e633302ace1 ("scsi: lpfc: vmid: Add support for VMID in mailbox command") introduced allocations for the VMID resources in lpfc_create_port() after the call to scsi_host_alloc(). Upon failure on the VMID allocations, the new code would branch to the 'out' label, which returns NULL without unwinding anything, thus skipping the call to scsi_host_put(). Fix the problem by creating a separate label 'out_free_vmid' to unwind the VMID resources and make the 'out_put_shost' label call only scsi_host_put(), as was done before the introduction of allocations for VMID.

Źródła

Alerty bezpieczeństwa

Dostawaj alerty CVE zanim staną się incydentem

Wysyłamy wybrane zagrożenia infrastrukturalne po polsku, z praktycznym komentarzem dla środowisk DataHouse.

  • DataHouse: administracja serwerów i bezpieczna chmura
  • Hostilla.pl: hosting i usługi pocztowe
  • SecDNS.pl: bezpłatna warstwa bezpieczeństwa DNS